Slim, Space-saving, 4-point Unit Relay
|
Not currently certified by any standards
Features
1.Slim, space-saving type (33 mm 1.299 inch wide) with four independent points on a base measuring 33 × 67 mm 1.299 × 2.638 inch. This contributes to a more compact control panel.
2.PA relays, which have high sensitivity Au clad twin contacts, are installed.
PA relays, 5 mm .197 inch wide, are installed.
The PA relays feature high sensitivity (12 V type: 120 mW, 24 V type: 180 mW) and twin contacts with Au-cladding, which combine to ensure high reliability even with minute loads.
3.Can be mounted on a DIN rail or mounted directly (by screw).
4.Equipped with an LED display to allow easy confirmation of operation.
5.Possible to select relay for use in the 4-point terminal in accordance with load.
Rating/ Performance
1.RT-3 Unit relay
1. Input ratings (per PA relay)
Part No. | Rated input voltage |
Input current (at rated input voltage, 20°C 68℉) (approx.) |
Allowable variation of rated input voltage (-20 to +55°C - 4 to +131℉) |
---|---|---|---|
RT3S-12V |
12 V DC
|
11.5 mA (Relay 10 mA + LED 1.5 mA) |
12 V DC ± 10%
|
RT3S-24V |
24 V DC
|
10.5 mA (Relay 7.5 mA + LED 3 mA)
|
24 V DC ± 10%
|
2. PA Relay coil specifications (reference value)
Relay part No. |
Pick-up voltage (Initial) (at 20°C 68℉) |
Drop-out voltage (Initial) (at 20°C 68℉) |
Coil resistance (±10%) (at 20°C 68℉) |
Nominal operating power |
---|---|---|---|---|
PA1a-12V | 70%V or less of nominal voltage | 5%V or more of nominal voltage | 1,200 Ω | 120 mW |
PA1a-24V | 3,200 Ω | 180 mW |
3. Output ratings (per PA relay)
Specification | Item | Specifications |
---|---|---|
Contact rating | Rated control capacity (resistive load) | 3 A 250 V AC, 3 A 30 V DC |
Maximum allowable contact power (resistive load) | 750 VA (AC), 90 W (DC) | |
Maximum allowable contact voltage | 250 V AC, 30 V DC | |
Maximum allowable contact current | 3 A | |
Minimum load (reference value) | 100 mV 100 μA | |
Expected life | Electrical (resistive load) |
Min. 3 × 104: 3 A 250V AC Min. 3 × 104: 3 A 30V DC Min. 105: 2 A 250V AC Min. 105: 2 A 30V DC |
Mechanical | Min. 2 × 107 (at 180times/min.) |
* | During 4-point simultaneous operation, the rating per point is also as shown above. |
---|
2.4-point Terminal
1. Input ratings (per relay)
Rated input voltage | Allowable variation of rated input voltage | Allowable input current |
---|---|---|
12, 24 V DC | 12 V DC ±10%, 24 V DC ±10% | 0.2A |
* | The input voltage value above is the allowable current when no relay is installed. Please note that input voltage is determined by the type of relay installed. |
---|
2. Input rating when PA relay installed (per relay, at 20°C 68°F)
Type | Rated voltage input | Operate voltage (Initial) | Release voltage (Initial) |
Input current (during application of rated input voltage) |
---|---|---|---|---|
PA1a-12V | 12 V DC |
Max. 9.5V DC (Relay max. 8.4V + include diode max. 1.1V) |
Min. 1.0V DC (Relay min. 0.6V + include diode min. 0.4V) |
Approx. 11.5mA (Relay 10mA + LED 1.5mA) |
PA1a-24V | 24 V DC |
Max. 17.9V DC (Relay max. 16.8V + include diode max. 1.1V) |
Min. 1.6V DC (Relay min. 1.2V + include diode min. 0.4V) |
Approx. 10.5mA (Relay 7.5mA + LED 3mA) |
3. Input rating when PhotoMOS Power voltage sensitive type installed (per relay, at 25°C 77°F)
Type |
Rated voltage input |
Operate voltage (Initial) | Release voltage (Initial) |
Input current (during application of rated input voltage) |
---|---|---|---|---|
AQZ*0*D | 12, 24V DC |
Max. 5.1V DC (Relay max. 4.0V + include diode max. 1.1V) |
Min. 1.2V DC (Relay min. 0.8V + include diode min. 0.4V) |
Approx. 10.0mA (Relay 7.0mA + LED 3mA) |
4. Output rating (per relay)
Allowable load voltage | Allowable load current |
---|---|
600V (DC), 600V (AC peak value) | 3A |
* |
The value above is the allowable value when no relay is installed. Please note that limitations apply to the load voltage and current depending on the type of relay installed. |
---|
5. Output rating when PA relay installed (per relay, at 20°C 68°F)
Specification | Item | Specifications |
---|---|---|
Contact rating | Rated control capacity (resistive load) | 3 A 250 V AC, 3 A 30 V DC |
Maximum allowable contact power (resistive load) | 750 VA (AC), 90 W (DC) | |
Maximum allowable contact voltage | 250 V AC, 30 V DC | |
Maximum allowable contact current | 3 A | |
Minimum load (reference value) | 100 mV 100 μA | |
Expected life | Electrical (resistive load) |
Min. 3×104: 3 A 250V AC, 3 A 30V DC Min. 105: 2 A 250V AC, 2 A 30V DC |
Mechanical | Min. 2×107 (at 180 times/min.) |
* | During 4-point simultaneous operation, the rating per point is also as shown above. |
---|
6. Output rating when PhotoMOS Power Voltage-sensitive type installed (per relay, at 25°C 77°F)
Possible relays |
Maximum load voltage (DC, AC peak value) |
Continuous load current (DC, AC peak value) |
Possible relays |
Maximum load voltage (DC, AC peak value) |
Continuous load current (DC, AC peak value) |
||
---|---|---|---|---|---|---|---|
Type | Part No. | Type | Part No. | ||||
DC only | AQZ102D | 60V | 1.80A |
AC, DC dual use |
AQZ202D | 60V | 1.350A |
AQZ105D | 100V | 1.15A | AQZ205D | 100V | 0.900A | ||
AQZ107D | 200V | 0.55A | AQZ207D | 200V | 0.450A | ||
AQZ104D | 400V | 0.30A | AQZ204D | 400V | 0.225A |
*1 | During 4-point simultaneous operation, the rating per point is also as shown above. |
---|---|
*2 | Please use a load current that is within the range of the data given below in "Reference data Load current vs. ambient temperature characteristics". |
Specifications
RT-3 Unit relay/4-point Terminal
Item | Specifications | Condition | |
---|---|---|---|
Breakdown voltage | Between input and output | 2,000 Vrms | for 1 min. |
Between different terminals (between relays, both ways) | 1,500 Vrms | for 1 min. | |
Insulation resistance | Min. 100 MΩ (Measurement at same location as “Breakdown voltage” section.) | Using 500 V DC megger | |
Vibration resistance (destructive) |
10 to 55 Hz at double amplitude 1 mm .039 inch |
In vertical, horizontal and longitudinal directions | |
Vibration resistance (functional) |
10 to 55 Hz at double amplitude 1 mm .039 inch |
||
Shock resistance (destructive) | Min. 196 m/s2 | In vertical, horizontal and longitudinal directions | |
Shock resistance (functional) | Min. 98 m/s2 | In vertical, horizontal and longitudinal directions | |
Ambient temperature | -20°C to +55°C - 4°F to +131°F | Not freezing and condensing | |
Ambient humidity | 35% to 85% R.H. | Not condensing | |
Storage temperature | -30°C to +80°C -22°F to +176°F | Not freezing and condensing | |
Terminal screw fasten torque | 0.3 to 0.5 Nm | ||
Coil surge absorber | Diode (1 A, 400 V) | ||
Cross connection protecting diode | 1 A, inverse voltage 400 V | ||
Unit weight | Approx. 100 g 3.53 oz |
*1 | The value of breakdown voltage and insulation resistance is the initial one. |
---|---|
*2 | Condensing occurs when the unit relay is exposed to sudden temperature change in a high temperature and high humidity atmosphere. This may cause some troubles like insulation failure of the socket or the print circuit board. Take care under this condition. |
*3 | Below 0°C 32°F, condensing water can freeze and cause socket contact failures and other problems. Take care under this condition. |
Reference data
1. Maximum value for switching capacity(output)
Per PA relay
|
2. Load current vs. ambient temperature characteristics (DC only)
|
3. Load current vs. ambient temperature characteristics (AC/DC dual use)
|
1.Dimensions
|
|
|
Option
*Approved for all the optional products. |
- Unit : mm/inch
Short circuit plate
Use when you want to bridge terminals.
|
|
|
|